Light radiation safety test system/IEC62471

MOQ :1 set

Lead Time :30 Days

Product details

Supply Ability

  • Supply Ability:2 piecesWarranty(Year):1 Year

Packaging & Delivery

  • Length:600 cmWidth:200 cm
  • Height:150 cmLogistics Weight:600.000 kg/set
  • Packaging:1 set

Product Specifications

  • Brand name:Linkcolor

Product Description

LRS-308 Light radiation safety test systems, mainly for LED products, UV light, optical radiation safety testing and rating evaluation of lighting and lamps. Including the skin and eyes ultraviolet photochemical damage, near UV eye damage, retinal thermal hazards, eye and skin thermal radiation hazards.

Measuring the full-band UV-visible light (200nm ~ 3000nm) spectral power distribution of ultraviolet radiation power, biologically effective ultraviolet radiation energy (eg: sterilization, light-induced conjunctivitis, keratitis photo, UV erythema, pigmentation, there is crystalline and aphakic retinal damage), parameter illuminance, chromaticity coordinates, color temperature, color rendering index and source of electrical parameters.

 

The condition of software:

(1) Ultraviolet radiation safety testing of lighting 

(2) Effective UV radiation source test

(3) Light source and lamps photometric, colorimetric testig

(4) UV and visible spectral irradiance data and distribution curve

 

Part of the ultraviolet measurement content and related standards :

(1) Measuring reflection lights and lighting fixtures ultraviolet radiation (protection factor) (UV-Radiation, and mw / cm2 / klx).

(2) Measuring health phototherapy with ultraviolet radiation source of ultraviolet spectrum distribution, ultraviolet radiation illuminance (mw / cm2), the effective UV irradiance (mw / cm2), A, B, and C-band effective irradiance (mw / cm2)

 

Test reference standard as follows:

GB/T 20145-2006;

IEC 62471 Lamps and lamp systems photobiological safety test system 

CIE S009

GB7000.1 General safety requirements and test fixtures

IEC/TR 62778,IEC/EN 60598 Annex P.,IEC/EN 60432 : Incandescent Lamp UV radiation,IEC/EN 60335-2-27 ,IEC  0335-2-59 :clause 32,2005/32/EC

 

Hazard Classification

(1) Photochemical UV damage (200-400nm) 

(2) Near ultraviolet hazard (315-400nm)

(3) Blu-ray harm (300-700nm) 

(4) Blue hazard - small light (300-700nm) 

(5) Retinal thermal hazards (380-1400nm) 

(6) The thermal damage to the retina weak visual stimuli (780-1400nm) 

(7) 780-3000nm

(8) 380-3000nm